Maintenance Manual for Collaborative Robot
English
English
  • Maintenance Manual for Collaborative Robot
  • About this manual
    • Copyright
    • Notation rules
    • Safety precautions
  • 1. Safety
    • 1.1 Safety requirements
      • 1.1.1 Applicable standards
      • 1.1.2 Safety performance
    • 1.2 Safety measures
      • 1.2.1 Safety functions
      • 1.2.2 Safety training
      • 1.2.3 Safety labels
      • 1.2.4 Emergency stop
        • 1.2.4.1 Emergency stop switches
        • 1.2.4.2 Connecting to emergency stop devices of external systems
    • 1.3 Risk assement
    • 1.4 Potential risk
    • 1.5 Validity and responsibilities
  • 2. Introduction to the product
    • 2.1 Intended uses of the product
    • 2.2 Product components
    • 2.3 Part names
      • 2.3.1 Manipulator
      • 2.3.2 Controller
      • 2.3.3 Teach pendant
    • 2.4 Nameplate
  • 3. Product installation
    • 3.1 Environment of installation and preparation
      • 3.1.1 Environments of installation and use
      • 3.1.2 Spaces of the robot system
      • 3.1.3 Allowable limit of wrist axis load
      • 3.1.4 Payload
    • 3.2 Product installation
      • 3.2.1 Composition of robot systems
      • 3.2.2 Robot and controller installation
        • 3.2.2.1 Mounting plate installation
      • 3.2.3 Tool connection
      • 3.2.4 Wiring
      • 3.2.5 Power on
    • 3.3 Robot interface
      • 3.3.1 Tool flange connection point
        • 3.3.1.1 T4071017041-001 (TE) pin map
        • 3.3.1.2 T41171130012-001 (TE) pin map
        • 3.3.1.3 Air hose
      • 3.3.2 External device interface
        • 3.3.2.1 Terminal block (TB1): common analog I/O signals
        • 3.3.2.2 Terminal block (TB2): dedicated safety signal input
        • 3.3.2.3 Terminal block (TB3): system signal I/O
        • 3.3.2.4 D-sub 25-pin connector (SDIO): common digital I/O
        • 3.3.2.5 D-sub 9-pin connector (COM1, COM2): serial communication (RS485, 422)
    • 3.4 Stopping distance and time
      • 3.4.1 STOP 0
      • 3.4.2 STOP1
    • 3.5 Safety setting
    • 3.6 Programming and restarting
    • 3.7 Axis limiting devices
    • 3.8 Movement without drive power
    • 3.9 Other safety precautions
  • 4. Maintenance
    • 4.1 Checking of the collaborative robot
      • 4.1.1 Check sheet
      • 4.1.2 Wiring check
      • 4.1.3 Bolt check
    • 4.2 Maintenance of the collaborative robot
      • 4.2.1 Replacement of internal wiring
      • 4.2.2 Replacement of the integrated driving module
        • 4.2.2.1 Replacement timing
        • 4.2.2.2 Weight of the integrated driving module
        • 4.2.2.3 Tools and parts
        • 4.2.2.4 Recommended posture in disassembling the integrated driving module
        • 4.2.2.5 Method for replacing the integrated driving module
      • 4.2.3 Encoder backup battery replacement
      • 4.2.4 Grease replacement
    • 4.3 Controller check and maintenance
      • 4.3.1 Internal structure
      • 4.3.2 Safety control module
        • 4.3.2.1 Connection and display
        • 4.3.2.2 Connection of I/O signals for the robot system (TBSYS1)
        • 4.3.2.3 Safety I/O signal connection (TBSDI, TBSDO)
        • 4.3.2.4 Connection of common digital I/O signals (TBDIO)
        • 4.3.2.5 Connection of common digital I/O signals (TBAIO)
        • 4.3.2.6 Information on major components
      • 4.3.3 Power precharge module (PPM)
        • 4.3.3.1 Connection and display
        • 4.3.3.2 Information on major components
      • 4.3.4 Regenerative discharge module (RDM)
        • 4.3.4.1 Connection and display
        • 4.3.4.2 Information on major components
      • 4.3.5 Microcomputer module
      • 4.3.6 Power supply
      • 4.3.7 Teach pendant
      • 4.3.8 PCI communication card (optional)
        • 4.3.8.1 Connect pin map
  • 5. Moving and storing
    • 5.1 Moving method
      • 5.1.1 Recommended posture
      • 5.1.2 Packaging box
      • 5.1.3 Cautions
    • 5.2 Storing method
    • 5.3 Disposal
  • 6. Appendix
    • 6.1 Block diagrams
      • 6.1.1 YL012 S-axis
      • 6.1.2 YL012 H-axis
      • 6.1.3 YL012 V-axis
      • 6.1.4 YL012 R-axis
      • 6.1.5 YL012 B-axis
      • 6.1.6 YL012 R1-axis
      • 6.1.7 YL012 tool flange
      • 6.1.8 Power connector
    • 6.2 System specifications
      • 6.2.1 Collaborative robot
      • 6.2.2 Controller
      • 6.2.3 Teach pendant
  • Certifications
  • Attachment
    • Rules on Occupational Safety and Health Standards, and Notice for Safety Inspection
  • Quality Assurance
Powered by GitBook
On this page

Was this helpful?

  1. 4. Maintenance
  2. 4.3 Controller check and maintenance
  3. 4.3.3 Power precharge module (PPM)

4.3.3.2 Information on major components

The PPM utilizes small power resistors to prevent inrush current and is connected serially to the charging system. Because the opening/closing of the charging system may have a significant impact on the system, the PPM utilizes safety relays for state monitoring.

Component

Usage

   Specification

Resistor for preventing inrush current (RC1)

Prevention of inrush current during precharging

  • PQR10 10Ω

  • 10W (Ceramic Wire Wound Resistor)

Safety relay (SR1)

Opening/closing of the precharging system

  • V23047-A1024-A501

  • 5A, 250VAC

  • Force-guided Relay

Previous4.3.3.1 Connection and displayNext4.3.4 Regenerative discharge module (RDM)