4.3.2.2 Connection of I/O signals for the robot system (TBSYS1)
Last updated
Was this helpful?
Last updated
Was this helpful?
The I/O signals dedicated to the robot system are connected through TBSYS1, the terminal block of the safety control module.
* The pins 3 through 8 and 11 through 16 are used as dedicated signals inside the control system.
No.
Name
Usage
1
SF_POW1
Protective stop input common (Channel 1)
2
SF_POW2
Protective stop input common (Channel 2)
3
SF_POW1
Emergency stop input common (Channel 1) - Connection of the emergency stop switch of the control box
4
SF_POW2
Emergency stop input common (Channel 2) - Connection of the emergency stop switch of the control box
5
IN_POW1
PRIN input common
6
IN_POW2
Reserved signal input common
7
SF_GND1
PRON output common
8
SF_GND2
Reserved signal output common
9
SG1
Protective stop input (Channel 1)
10
SG2
Protective stop input (Channel 2)
11
ES1
Emergency stop input (Channel 1) - Connection of the emergency stop switch of the control box
12
ES2
Emergency stop input (Channel 2) - Connection of the emergency stop switch of the control box
13
/PRIN
Precharge relay state input
14
RSV_IN2
Reserved signal input
15
/PRON
Precharge relay actuation output
16
RSV_OUT2
Reserved signal output