4.3.2.2 Connection of I/O signals for the robot system (TBSYS1)

The I/O signals dedicated to the robot system are connected through TBSYS1, the terminal block of the safety control module.

Figure 29 Connection of I/O signals for the robot system (TBSYS1)

* The pins 3 through 8 and 11 through 16 are used as dedicated signals inside the control system.

No.

Name

       Usage

1

SF_POW1

Protective stop input common (Channel 1)

2

SF_POW2

Protective stop input common (Channel 2)

3

SF_POW1

Emergency stop input common (Channel 1) - Connection of the emergency stop switch of the control box

4

SF_POW2

Emergency stop input common (Channel 2) - Connection of the emergency stop switch of the control box

5

IN_POW1

PRIN input common

6

IN_POW2

Reserved signal input common

7

SF_GND1

PRON output common

8

SF_GND2

Reserved signal output common

9

SG1

Protective stop input (Channel 1)

10

SG2

Protective stop input (Channel 2)

11

ES1

Emergency stop input (Channel 1) - Connection of the emergency stop switch of the control box

12

ES2

Emergency stop input (Channel 2) - Connection of the emergency stop switch of the control box

13

/PRIN

Precharge relay state input

14

RSV_IN2

Reserved signal input

15

/PRON

Precharge relay actuation output

16

RSV_OUT2

Reserved signal output