Hi6 Robot Controller Manual - Robot Language HRScr
English
English
  • Hi6 Robot Controller Function Manual - Robot Language HRScript
  • 1. Overview
    • 1.1 Introduction of HRScript
  • 2. Basic Syntax
    • 2.1 Statements
    • 2.2 Identifiers
    • 2.3 Types of Statements
      • 2.3.1 Procedures
      • 2.3.2 Assignment Statements
      • 2.3.3 Comment Statements
      • 2.3.4 Labels
    • 2.4 First Program – Hello, World!
    • 2.5 Data Type
      • 2.5.1 String Data Type
      • 2.5.2 Number Data Type
      • 2.5.3 Boolean Data Type
      • 2.5.4 Array Type and Object Type
    • 2.6 Variables
    • 2.7 Binary and Hexadecimal
    • 2.8 Operators and Expressions
    • 2.9 Functions
      • 2.9.1 Math Functions
      • 2.9.2 String Functions
      • 2.9.3 Date and Time Functions
      • 2.9.4 Constructor Functions
      • 2.9.5 Other Functions
  • 3. Flow-Control Statements and Sub-Program
    • 3.1 Address
    • 3.2 Stop or Wait Statement
      • 3.2.1 stop
      • 3.2.2 end
      • 3.2.3 delay
      • 3.2.4 wait
    • 3.3 Branch Statement
      • 3.3.1 goto
    • 3.4 Conditional Statements
      • 3.4.1 Single-Line if
      • 3.4.2 if-endif
      • 3.4.3 if-else-endif Statement
      • 3.4.4. if-elseif-else-endif
      • 3.4.5 switch-case-break-end_switch
    • 3.5. Nested Flow-Control Statements
    • 3.6 Loop Statements
      • 3.6.1 for-next
    • 3.7 Call, Jump Statement and Subprograms
      • 3.7.1 call
      • 3.7.2 Parameters and param, return
      • 3.7.3 jump
    • 3.8 Local Variables and Global Variables
      • 3.8.1 Local Variables
      • 3.8.2 Global Variables
      • 3.8.3 Precedence
  • 4. Arrays and Objects
    • 4.1 Arrays
      • 4.1.1 Arrays
      • 4.1.2 Multidimensional Arrays
      • 4.1.3 Array Constructor Function
    • 4.2 Object
    • 4.3 Copied assignment of arrays and objects
    • 4.4 Call-by-reference and call-by-value
  • 5. Moving a Robotwith Robot Language
    • 5.1 Pose
    • 5.2 Shift
    • 5.3 Pose Expression
    • 5.4 move
    • 5.5 User Coordinate System (UCS)
  • 6. Communicating with External Devices
    • 6.1 FB Object: Digital I/O
      • 6.1.1 Input/Output Variables
      • 6.1.2 Examples
    • 6.2 ENet Module: Ethernet TCP/UDP Communication
      • 6.2.1 Constructor
      • 6.2.2 Member Variables
      • 6.2.3 Member Procedures
        • open
        • connect
        • send
        • recv
        • close
      • 6.2.4 Member Function
        • state
      • 6.2.5 Examples of TCP and UDP Communication
    • 6.3 Http_Cli Module: HTTP Client
      • 6.3.1 Constructor
      • 6.3.2 Member Variables
      • 6.3.3 Member Procedure
        • get
        • put
        • post
        • delete
      • 6.3.4 Examples of HTTP Client Communication
    • 6.4 Getting input from console bar
      • 6.4.1 input
Powered by GitBook
On this page

Was this helpful?

Edit on Git
  1. 2. Basic Syntax

2.1 Statements

The statement refers to each command string that becomes the execution unit of the job program. HRScript allows only one statement per line. Take note of how the four examples of statements are written below, particularly their appearances.

     move P,po3,spd=80%,accu=1,tool=3 until do33
10   z_pos = (base_height+offset)*1.05
     # robot has to wait sensor2 input
     *err_handle

For statements other than a step statement (move statements, etc.) that moves the robot, you can optionally add a line number (1 to 9999) at the beginning of the line. The number 10 in the second line is an example of a line number.

It does not matter if there are any number of spaces or tabs before and after the statement.

Proper indentation in statements is recommended for readability. Both spaces and tabs are allowed for indentation and do not affect the operation during execution.

Previous2. Basic SyntaxNext2.2 Identifiers

Last updated 3 years ago

Was this helpful?