Hi6 Robot Controller Manual - Robot Language HRScr
English
English
  • Hi6 Robot Controller Function Manual - Robot Language HRScript
  • 1. Overview
    • 1.1 Introduction of HRScript
  • 2. Basic Syntax
    • 2.1 Statements
    • 2.2 Identifiers
    • 2.3 Types of Statements
      • 2.3.1 Procedures
      • 2.3.2 Assignment Statements
      • 2.3.3 Comment Statements
      • 2.3.4 Labels
    • 2.4 First Program – Hello, World!
    • 2.5 Data Type
      • 2.5.1 String Data Type
      • 2.5.2 Number Data Type
      • 2.5.3 Boolean Data Type
      • 2.5.4 Array Type and Object Type
    • 2.6 Variables
    • 2.7 Binary and Hexadecimal
    • 2.8 Operators and Expressions
    • 2.9 Functions
      • 2.9.1 Math Functions
      • 2.9.2 String Functions
      • 2.9.3 Date and Time Functions
      • 2.9.4 Constructor Functions
      • 2.9.5 Other Functions
  • 3. Flow-Control Statements and Sub-Program
    • 3.1 Address
    • 3.2 Stop or Wait Statement
      • 3.2.1 stop
      • 3.2.2 end
      • 3.2.3 delay
      • 3.2.4 wait
    • 3.3 Branch Statement
      • 3.3.1 goto
    • 3.4 Conditional Statements
      • 3.4.1 Single-Line if
      • 3.4.2 if-endif
      • 3.4.3 if-else-endif Statement
      • 3.4.4. if-elseif-else-endif
      • 3.4.5 switch-case-break-end_switch
    • 3.5. Nested Flow-Control Statements
    • 3.6 Loop Statements
      • 3.6.1 for-next
    • 3.7 Call, Jump Statement and Subprograms
      • 3.7.1 call
      • 3.7.2 Parameters and param, return
      • 3.7.3 jump
    • 3.8 Local Variables and Global Variables
      • 3.8.1 Local Variables
      • 3.8.2 Global Variables
      • 3.8.3 Precedence
  • 4. Arrays and Objects
    • 4.1 Arrays
      • 4.1.1 Arrays
      • 4.1.2 Multidimensional Arrays
      • 4.1.3 Array Constructor Function
    • 4.2 Object
    • 4.3 Copied assignment of arrays and objects
    • 4.4 Call-by-reference and call-by-value
  • 5. Moving a Robotwith Robot Language
    • 5.1 Pose
    • 5.2 Shift
    • 5.3 Pose Expression
    • 5.4 move
    • 5.5 User Coordinate System (UCS)
  • 6. Communicating with External Devices
    • 6.1 FB Object: Digital I/O
      • 6.1.1 Input/Output Variables
      • 6.1.2 Examples
    • 6.2 ENet Module: Ethernet TCP/UDP Communication
      • 6.2.1 Constructor
      • 6.2.2 Member Variables
      • 6.2.3 Member Procedures
        • open
        • connect
        • send
        • recv
        • close
      • 6.2.4 Member Function
        • state
      • 6.2.5 Examples of TCP and UDP Communication
    • 6.3 Http_Cli Module: HTTP Client
      • 6.3.1 Constructor
      • 6.3.2 Member Variables
      • 6.3.3 Member Procedure
        • get
        • put
        • post
        • delete
      • 6.3.4 Examples of HTTP Client Communication
    • 6.4 Getting input from console bar
      • 6.4.1 input
Powered by GitBook
On this page

Was this helpful?

Edit on Git
  1. 2. Basic Syntax

2.2 Identifiers

Names must be given to commands, variables, functions, and labels that are described. These names are collectively referred to as “identifiers.” When deciding an identifier, it must comply with the following rules for the HRScript’s identifiers.

  • It must consist only of uppercase and lowercase letters, numbers, and underscores.

  • The first character must only be either a lowercase or uppercase letter or an underscore, not a number.

  • It should not contain a space or tab.

  • Identifiers already defined in the system, such as “if” and “for,” cannot be used.

  • There is no limit to the length.

The following shows correct and incorrect examples of identifiers:

myvar (O) 
myvar2 (O)
_myvar (O)
MyVar (O)
310a (X) – Started with a number
move (X) – An identifier already defined in the system
v300$ (X) – Used a symbol other than an underscore ($)
my var (X) – Included a space

Previous2.1 StatementsNext2.3 Types of Statements

Last updated 3 years ago

Was this helpful?