6.6 Public Input

Touch [public Input] in the panel selection window. Then, the public input signal window will appear.

You can check the status of public input signals that are inputted through the CNIN connector of the I/O board in the controller.

Figure 39 Public Input Signal – ON/OFF Status (Left) / Value Status (Right)
No.
Description

Displays the status of general input signals

  • General input signals designated as the system’s basic specifications or assigned by the user will be displayed in bold.

  • The signals currently being inputted will be displayed in yellow.

  • [FB0]: You can select the FB block to monitor by touching the drop-down menu (FB0 - FB15). You can configure up to 16 I/O blocks, and 960 points of signals can be monitored in

  • [ATTR.-APPLIED]: You can check the checkbox to perform the setting in a way that the physical input values are to be displayed before passing through the positive/negative logic attributes. The basic setting (unchecked) is that the input logic value after passing through the positive/negative logic attributes will be displayed.

  • [ON/OFF]/[Value]: You can change the signal display mode by touching the radio button.

  • In the case of using signals, such as fieldbus signals, by mapping them using an embedded PLC, the On/Off status of the input signals may appear differently.

  • The flow of the input signals is as follows.