E7101~E7120
Code
Message
Cause
Solutions
E7101
Error in the safety CPU (CH0) watchdog in the safety controller
Watchdog timeout of the safety CPU (CH0)
Reboot the controller.
If the error persists, replace the safety controller board.
E7102
Error in the safety CPU (CH1) watchdog in the safety controller
Watchdog timeout of the safety CPU (CH1)
Reboot the controller.
If the error persists, replace the safety controller board.
E7103
Error in the axis 1 encoder diagnosis by the safety controller
An error occurred during the axis 1 encoder diagnosis.
Check the CAN communication cable between the safety controller and the encoder.
Reboot the controller.
E7104
Error in the axis 2 encoder diagnosis by the safety controller
An error occurred during the axis 2 encoder diagnosis.
Check the CAN communication cable between the safety controller and the encoder.
Reboot the controller.
E7105
Error in the axis 3 encoder diagnosis by the safety controller
An error occurred during the axis 3 encoder diagnosis.
Check the CAN communication cable between the safety controller and the encoder.
Reboot the controller.
E7106
Error in the axis 4 encoder diagnosis by the safety controller
An error occurred during the axis 4 encoder diagnosis.
Check the CAN communication cable between the safety controller and the encoder.
Reboot the controller.
E7107
Error in the axis 5 encoder diagnosis by the safety controller
An error occurred during the axis 5 encoder diagnosis.
Check the CAN communication cable between the safety controller and the encoder.
Reboot the controller.
E7108
Error in the axis 6 encoder diagnosis by the safety controller
An error occurred during the axis 6 encoder diagnosis.
Check the CAN communication cable between the safety controller and the encoder.
Reboot the controller.
E7109
Error in the axis 1 torque sensor diagnosis by the safety controller
An error occurred during the axis 1 torque sensor diagnosis.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7110
Error in the axis 2 torque sensor diagnosis by the safety controller
An error occurred during the axis 2 torque sensor diagnosis.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7111
Error in the axis 3 torque sensor diagnosis by the safety controller
An error occurred during the axis 3 torque sensor diagnosis.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7112
Error in the axis 4 torque sensor diagnosis by the safety controller
An error occurred during the axis 4 torque sensor diagnosis.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7113
Error in the axis 5 torque sensor diagnosis by the safety controller
An error occurred during the axis 5 torque sensor diagnosis.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7114
Error in the axis 6 torque sensor diagnosis by the safety controller
An error occurred during the axis 6 torque sensor diagnosis.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7115
Error (2) in the axis 1 torque sensor diagnosis by the safety controller
An error occurred during the axis 1 torque sensor diagnosis.
Check if the tool data match the actual tool.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7116
Error (2) in the axis 2 torque sensor diagnosis by the safety controller
An error occurred during the axis 2 torque sensor diagnosis.
Check if the tool data match the actual tool.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7117
Error (2) in the axis 3 torque sensor diagnosis by the safety controller
An error occurred during the axis 3 torque sensor diagnosis.
Check if the tool data match the actual tool.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7118
Error (2) in the axis 4 torque sensor diagnosis by the safety controller
An error occurred during the axis 4 torque sensor diagnosis.
Check if the tool data match the actual tool.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7119
Error (2) in the axis 5 torque sensor diagnosis by the safety controller
An error occurred during the axis 5 torque sensor diagnosis.
Check if the tool data match the actual tool.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.
E7120
Error (2) in the axis 6 torque sensor diagnosis by the safety controller
An error occurred during the axis 6 torque sensor diagnosis.
Check if the tool data match the actual tool.
Check the CAN communication cable between the safety controller and the torque sensor.
Check the torque sensor of the pertaining axis.
Reboot the controller.