4.3.3.1 Connection and display
The connector layout, usage, and connecting devices used by the PPM are as follows:
Connector
Usage
External connecting device
CNPM3
Output terminal of the 48 V DC output power (for the motor)
Regenerative discharge module (RDM) CNPM3
CNPM4
Input terminal of the 48 V DC output power (for the motor)
Safety control module (SCM) CNPM3
CNEP1
Input terminal of the 48 V DC source power (for the motor)
Safety control module (SCM) CNEP1
CNPR
Control of the power charge function and connection of monitoring signals
Safety control module (SCM) TBSYS1
The details of the state display of the PPM are as follows:
LED
Usage
Display details
LEDY1
Indication of the state of operating
command for the relays that open/close the charging system
Lamp on: Under charging command
Lamp off: Not under charging command
LEDG1
Indication of the operating state of
the relays that open/close the charging system
Lamp on: Under charging
Lamp off: Not under charging
Last updated