The regenerative discharge board uses fuses for protecting components against overcurrent and a regenerative discharge resistor. The fuses are mounted at the upstream of the board and at the upstream of the regenerative discharge resistor, while the resistor is mounted at the downstream of the board. For the inside composition and component specifications, see the following figure and table.
Component
Usage
Specification
Thermal fuse
Protection from the overcurrent of regenerative operation and overheating of the regenerative discharge resistor
15 A, 93°C
Fuse for protecting from overcurrent of the input terminal
Protection from the overcurrent of input power
58 V, 20 A
Regenerative discharge resistor
Resistor for discharging regenerative current
5 Ω, 100 W