4.3.5 Microcomputer module
Last updated
Was this helpful?
Last updated
Was this helpful?
The microcomputer module (miniH6COM, EBC-GF53) drives and controls the collaborative robot based on the Hi6 control platform. For more details on this module, see “Operation Manual for Hi6 Controllers.”
The composition of the external interface, COM ports, and power connector of the microcomputer module is as follows:
Port
Usage
Specification
Count
DP
Display
Display Port
1
LAN1, LAN2, LAN3
Wired LAN
Giga LAN
3
USB1, USB2
USB
USB2.0
2
COM1, COM2
Serial communication
RS-232/422/485
2
GPIO
Digital I/O
8 bits, DSUB-9
1
DC IN
Power input
DC12 ~ 24V, 10A
1
-
Extension slot
PCIe x1, PCI
2
No
Name
No
Name
COMn_422_485_TX-
COMn_DSR#
COMn_422_485_TX+
COMn_RTS#
COMn_422_RX+
COMn_CTS#
COMn_422_RX-
COMn_RI_V#
GND
No
Name
No
Name
GPIO_GPIO0
GPIO_GPIO4
GPIO_GPIO1
GPIO_GPIO5
GPIO_GPIO2
GPIO_GPIO6
GPIO_GPIO3
GPIO_GPIO7
GND
No
Name
DC24V
FG
GND