4.3.5.2 Connectors of BD6C2
Last updated
Last updated
The placement of the connectors of the electronic board (BD6C2) is shown in the following figure, and the usage and connection devices for each are as shown in Table 4-39.
Table 4-42 Types and Usage of the Connectors of BD6C2
Name
Usage
Specification
CNAC
3-phase power input for control
3-phase 220V
CN220
CMSMPS power output
Single-phase 220V
CNFN1-4
AC fan power output
Single-phase 220V
CNPR1
Inrush current limiting circuit input
3-phase 220V, MC1 input side
CNPR2
Inrush current limiting circuit output
3-phase 220V, MC2 output side
CNBKAC
Brake SMPS input
Single-phase 220V
CNBKDC
Brake SMPS output
24VDC
CNPB1
Brake control power
24VDC, PB, BD640
CNPB2
Brake control power
24VDC, PB, Reserved
CNPRC
Inrush current limiting circuit control and monitoring
BD640 CNPRC
CNFPS1
CMSMPS power failure detection signal output 1
H6COM DIO
CNFPS2
CMSMPS power failure detection signal output 2
Reserved
CNMC1
Electronic contact MC1 control and monitoring
MC1
CNMC2
Electronic contact MC2 control and monitoring
MC2
CNMC
Electronic contact control and monitoring
BD630 CNMC
CN24VB
Control power input for each module
24VDC, CMBUFFER output
CN24VB1-8
Control power output for each module
24VDC, CN24VB for each module
CNBM
CMSMPS power failure detection signal input
CMSMPS 13–14